HF-Performer II for PL-T/C/R/L/TL5C lamps

HF-Performer 2 13-17 PL-T/C/R EII 220-240V

HF-Performer 2 13-17 PL-T/C/R EII 220-240V

  • An energy-efficient solution

    Product information

Videos

[trigger to render Video Gallery]

Images

Specifications Show all

General Characteristics
Application code
EII
Rated Lamptype
PL-T/C/R
Rated Number of Lamps
2 piece
Rated Ballast-Lamp Power
13-17
Line Voltage
220-240 V
Line Frequency
50/60 Hz
Energy Efficiency Index
A2
Lifetime 90% surv.@Tcaselife
50000 hr
Ignition Method
Warm Start
Operating Characteristics
Automatic restart
Yes
Ignition time
0.52 (max) s
Operating frequency
42 (min), 45 (nom) kHz
Mains voltage safety (AC)
-10%/+10%
Mains voltage performance (AC)
-8%/+6%
Inrush current Peak
18 (max) A
Inrush current Width
0.25 ms
Earth leakage current
0.5 mA
Power losses gear
2.63-3.26 W
Constant wattage deviation
-2%/+2%
Ballast Lumen Factor
1 -
PowerFactor 100% output power
0.95 -
Battery voltage lamp ignition
198-254 V
Battery voltage running lamps
176-254
Overvoltage protection 320Vac
48 hr
Overvoltage protection 350Vac
2 hr
Max ballast on MCB(16A type B)
28 x
Crestfactor
1.7 (max) -
Hum and Noise level
Inaudible
Total Harmonic Distortion EUR
10 %
Wiring Characteristics
Cable-Cap outputwires to earth
50 pF
Cable-Cap outputwires mutual
50 pF
Conn.type input terminals
Insert
Conn.type output terminals
Insert
Max. cable length Hot Wires
0.50 m
Striplength
7.5-8.5 mm
Dual fixture Master/Slave
Not applicable  [Master/Slave oper. not applicable]
Wcs Input terminals
0.50-1.50 mm2
Wcs Output terminals
0.50-1.50 mm2
System Chars on driver level
Rated Lamp Power on PL-T/C
13/17
Temperature Characteristics
T-case life
75 C
T-case maximum
75 (max) C
T-ignition
-25 (min), 50 (max) C
T-ambient
-25 (min), 50 (max) C
T-storage
-40 (min), 80 (max) C
Product Dimensions
Length A1
103.0 mm
Fixing Hole Distance Length A2
93.5 mm
Width B1
67.0 mm
Fixing Hole Distance Width B2
57.5 mm
Height C1
30.0 mm
Fixing Hole Diameter D1
4.5 mm
Approval & Application Chars
EMI 9kHz .. 30 MHz
EN 55015
EMI 30 MHz .. 1000MHz
EN 55022 level B  [Level = Class]
Safety Standard
IEC 61347-2-3
Performance Standard
IEC 60929
Quality Standard
ISO 9000:2000
Environmental Standard
ISO 14001
Harmonic current emissions
IEC 61000-3-2
EMC Immunity
IEC 61547
Vibrations
IEC 68-2-6 Fc
Bumps
IEC 68-2-29 Eb
Humidity
EN 61347-2-3 clause 11
Approval marks
ENEC / VDE-EMV
CE marking
Yes
Temperature marking
110  [Yes]
Emergency standard
IEC 60598-2-22
Product Data
Order code
914095 30
Full product code
871150091409530
Full product name
HF-P 2 13-17 PL-T/C/R EII 220-240V
Order product name
HF-P 2 13-17 PL-T/C/R EII 220-240V
Pieces per pack
1
Packing configuration
12
Packs per outerbox
12
Bar code on pack - EAN1
8711500914095
Bar code on outerbox - EAN3
8711500914101
Logistic code(s) - 12NC
913700631266
Net weight per piece
0.150 kg
Successor order code
Installation Diagrams
HF-Performer 2 13-17 PL-T/C/R EII 220-240V
HF-Performer 2 13-17 PL-T/C/R EII 220-240V

Recently Viewed

    • Manage your projects with MyProjects
      Use MyProjects to create, save manage and share items and projects with you colleagues and team members.
You are now visiting our Global professional lighting website, visit your local website by going to the USA website